OAR 330-070-0064
Photovoltaic AEDs


(1)

Installations of photovoltaic systems must be installed according to manufacturer’s instructions, comply with all applicable Oregon codes and be verified by a tax-credit technician.

(2)

System size will be determined by the sum of all the photovoltaic module DC wattage ratings under standard test conditions (STC). The minimum system size must be 200 Watts DC output under STC.

(3)

All modules must have a minimum Total Solar Resource Fraction (TSRF) of 75 percent over the entire module. Solar electric AC modules with a TSRF of less than 75 percent will not be counted in the system size.

(4)

The department may verify that the modules and inverters are listed on the California Energy Commission (CEC) eligible list as of the date of the application.
[Publications: Publications referenced are available from the agency.]