690–230–0005
Policy and Purpose
690–230–0020
Definitions
690–230–0030
Construction of Low-Temperature Geothermal Production and Injection Wells
690–230–0040
Location of Low-Temperature Geothermal Injection Wells Not Exceeding 15,000 Gallons Per Day
690–230–0045
Location of Low-Temperature Geothermal Injection Wells Exceeding 15,000 Gallons Per Day
690–230–0050
Description of Proposed Well Use (Start Card)
690–230–0060
Identification of Intended Well Use (Well Log)
690–230–0070
Well-Head Protection Equipment
690–230–0075
Disposal of Low-Temperature Geothermal Fluids Produced During Drilling and Testing
690–230–0080
Pump Testing of Low-Temperature Geothermal Injection Wells with an Anticipated Injection Rate of Less than 15,000 Gallons Per Day
690–230–0085
Pump Testing of Low-Temperature Geothermal Injection Wells with an Anticipated Injection Rate Exceeding 15,000 Gallons Per Day
690–230–0090
Water Temperature Measurement
690–230–0100
Additional Standards for Low-Temperature Geothermal Injection Wells
690–230–0110
Injection Plan for Wells with an Anticipated Injection Rate Not Exceeding 15,000 Gallons Per Day
690–230–0115
Injection Plan for Wells with an Anticipated Injection Rate Exceeding 15,000 Gallons Per Day
690–230–0120
Water Rights Procedure Processing of Applications
690–230–0130
Exemption from Water Right Permit Application/Use of Low-Temperature Geothermal Fluid
690–230–0140
Water Right Limitation for Nonstandard Effluent Disposal Systems
Last Updated

Jun. 8, 2021

Rule 690-230-0120’s source at or​.us