OAR 340-073-0026
Septic Tanks


(1)

Septic tanks must be constructed of concrete, fiberglass, steel, or other non-corrosive materials approved by the department.

(2)

Steel septic tanks must be manufactured with 12-gauge or thicker steel. They must be coated inside and out with asphalt or other protective coatings that meet the American National Standards Institute UL 70 standard, Sections 25 through 43, or other coatings of equal or better performance approved by the department.
340‑073‑0025
Tank Construction
340‑073‑0026
Septic Tanks
340‑073‑0030
Dosing Septic Tank
340‑073‑0035
Distribution Boxes, Drop Boxes, and Diversion Valves: Distribution Boxes
340‑073‑0040
Distribution Boxes, Drop Boxes, and Diversion Valves: Drop Boxes
340‑073‑0041
Distribution Boxes, Drop Boxes, and Diversion Valves: Filter Fabric
340‑073‑0045
Distribution Boxes, Drop Boxes, and Diversion Valves: Diversion Valves
340‑073‑0050
Distribution Boxes, Drop Boxes, and Diversion Valves: Dosing Tanks
340‑073‑0055
Distribution Boxes, Drop Boxes, and Diversion Valves: Dosing Assemblies: Effluent Pumps, Controls and Alarms, and Dosing Siphons
340‑073‑0056
Distribution Boxes, Drop Boxes, and Diversion Valves: Effluent Filters
340‑073‑0060
Distribution Boxes, Drop Boxes, and Diversion Valves: Pipe Materials and Construction
340‑073‑0065
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Privies and Portable Toilet Shelters
340‑073‑0070
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Unsealed Earth Pits for Privies
340‑073‑0075
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Self-Contained Nonwater-Carried Toilet Facilities
340‑073‑0080
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Construction of Gray Water Waste Disposal Sumps
340‑073‑0085
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Flexible Membrane Liners for Sand Filters Treating Septic Tank Effluent
Last Updated

Jun. 8, 2021