General Standards. All self-contained, nonwater-carried toilet facilities must comply with the following requirements.

(a)

They must have water-tight chambers constructed of reinforced concrete, plastic, fiberglass, metal, or other material of acceptable durability and corrosion resistance, approved by the department, and designed to facilitate the removal of the wastes.

(b)

Black wastes must be stored in an appropriate chamber until removal for final treatment elsewhere. Wastes must be removed from the chamber whenever necessary to prevent overflow.

(c)

Chemicals containing heavy metals such as copper, cadmium, and zinc, must not be used in self-contained toilet facilities.

(d)

All surfaces subject to soiling must be impervious, easily cleanable, and readily accessible.

(2)

Vault Toilet Facilities.

(a)

The capacity of vaults must be at least 350 gallons or, in places of employment, 100 gallons per seat.

(b)

Caustic must be added routinely to vault chambers to control odors.

(3)

Chemical Toilet Facilities.

(a)

Toilet bowls must be constructed of stainless steel, plastic, fiberglass, ceramic, or other material approved by the department.

(b)

Waste passages must have smooth surfaces and be free of obstructions, recesses, or cross braces that would restrict or interfere with flow of black wastes.

(c)

Biocides and oxidants must be added to waste detention chambers at rates and intervals recommended by the chemical manufacturer and approved by the department.

(d)

Chambers and receptacles must provide a minimum storage capacity of 50 gallons per seat.

(e)

Portable shelters housing chemical toilets must display the business name of the licensed sewage disposal service that is responsible for servicing them.

Source: Rule 340-073-0075 — Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Self-Contained Nonwater-Carried Toilet Facilities, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=340-073-0075.

340‑073‑0025
Tank Construction
340‑073‑0026
Septic Tanks
340‑073‑0030
Dosing Septic Tank
340‑073‑0035
Distribution Boxes, Drop Boxes, and Diversion Valves: Distribution Boxes
340‑073‑0040
Distribution Boxes, Drop Boxes, and Diversion Valves: Drop Boxes
340‑073‑0041
Distribution Boxes, Drop Boxes, and Diversion Valves: Filter Fabric
340‑073‑0045
Distribution Boxes, Drop Boxes, and Diversion Valves: Diversion Valves
340‑073‑0050
Distribution Boxes, Drop Boxes, and Diversion Valves: Dosing Tanks
340‑073‑0055
Distribution Boxes, Drop Boxes, and Diversion Valves: Dosing Assemblies: Effluent Pumps, Controls and Alarms, and Dosing Siphons
340‑073‑0056
Distribution Boxes, Drop Boxes, and Diversion Valves: Effluent Filters
340‑073‑0060
Distribution Boxes, Drop Boxes, and Diversion Valves: Pipe Materials and Construction
340‑073‑0065
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Privies and Portable Toilet Shelters
340‑073‑0070
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Unsealed Earth Pits for Privies
340‑073‑0075
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Self-Contained Nonwater-Carried Toilet Facilities
340‑073‑0080
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Construction of Gray Water Waste Disposal Sumps
340‑073‑0085
Non-water-Carried Waste Disposal Facilities, Materials, and Construction: Flexible Membrane Liners for Sand Filters Treating Septic Tank Effluent
Last Updated

Jun. 8, 2021

Rule 340-073-0075’s source at or​.us