OAR 411-087-0360
Hallways, Corridors and Stairways


(1)

Dimensions. All resident corridors/hallways serving resident living areas shall be a minimum of eight feet in width.

(2)

Obstructions. Items such as drinking fountains, telephone booths, vending machines, and portable equipment shall be located so as not to restrict corridor traffic or reduce the corridor width below the required minimum.

(3)

Handrails:

(a)

Handrails shall be provided on both sides of corridors used by residents and on all stairways. A minimum clear distance of 1-12 inches (3.8 cm) shall be provided between the handrail and the wall;

(b)

Ends of handrails shall be returned to the wall or otherwise be constructed to prevent snagging the clothes of residents.

(4)

Exceptions. Except as provided in OAR 411-087-0010 (New and Old Construction, Remodeling, Certificate of Need), facilities continuously licensed since January 1, 1992 shall be exempt from sections (1) and (2) of this rule.

Source: Rule 411-087-0360 — Hallways, Corridors and Stairways, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=411-087-0360.

Last Updated

Jun. 8, 2021

Rule 411-087-0360’s source at or​.us