OAR 738-070-0110
Standards for Determining Obstructions
(1)
An existing object, including a mobile object, is, and a future object would be, an obstruction to air navigation if it is of greater height than any of the following heights or surfaces:(a)
A height of 500 feet above ground level at the site of the object;(b)
A height that is 200 feet above ground level or above the established airport elevation, whichever is higher, within three nautical miles of the established reference point of an airport, excluding heliports, with its longest runway more than 3,200 feet in actual length, and that height increases in the proportion of 100 feet for each additional nautical mile of distance from the airport up to a maximum of 500 feet;(c)
A height within a terminal obstacle clearance area, including an initial approach segment, a departure area, and a circling approach area, which would result in the vertical distance between any point on the object and an established minimum instrument flight altitude within that area or segment to be less than the required obstacle clearance;(d)
A height within an enroute obstacle clearance area, including turn and termination areas, of a federal airway or approved off-airway route, that would increase the minimum obstacle clearance altitude;(e)
The surface of a take-off and landing area of an airport or any imaginary surface established under OAR 738-070-0120 (Civilian Airport Imaginary Surfaces) or 738-070-0130 (Airport Imaginary Surfaces for Heliports). However, no part of the take-off or landing area itself will be considered an obstruction.(2)
Except for traverse ways on or near an airport with an operative ground traffic control service, furnished by an air traffic control tower or by the airport management and coordinated with the Federal Aviation Administration’s air traffic control service, the standards of section (1) of this rule apply to traverse ways used or to be used for the passage of mobile objects only after the heights of these traverse ways are increased by:(a)
17 feet for an interstate highway that is part of the National System of Military and Interstate Highways, where overcrossings are designed for a minimum of 17 feet vertical distance;(b)
15 feet for any other public roadway;(c)
10 feet or the height of the highest mobile object that would normally traverse the road, whichever is greater, for a private road;(d)
23 feet for a railroad;(e)
For a waterway or any other traverse way not previously mentioned, an amount equal to the height of the highest mobile object that would normally traverse it.
Source:
Rule 738-070-0110 — Standards for Determining Obstructions, https://secure.sos.state.or.us/oard/view.action?ruleNumber=738-070-0110
.