OAR 918-020-0390
Alternative Approval Process for Single-Family Dwelling Conversions


(1)

A municipality administering and enforcing a building inspection program under ORS 455.148 (Comprehensive municipal building inspection programs) or 455.150 (Selective municipal building inspection programs) shall, upon written request from an applicant for a building permit, exercise its ability to grant a local alternate approval, including alternate methods, modifications, and waivers under the state building code for projects related to conversion of a single-family dwelling to no more than four dwelling units. When making decisions regarding such a permit application, a building official may grant an alternate method for the following elements:

(a)

Means of egress requirements, including emergency escape and rescue openings;

(b)

Smoke alarms, carbon monoxide alarms, and radon gas mitigation;

(c)

Fire separation, fire resistance ratings, and dwelling unit penetrations and compartmentalization; and

(d)

Required automatic fire sprinkler systems.

(2)

In making decisions related to an alternate method for conversion of an existing single-family dwelling into no more than four dwelling units, a building official may consider whether an automatic sprinkler system is technically feasible and consider alternate methods and materials, provided that adequate safeguards exist to address the items listed in section (1) of this rule and other appropriate measures are in place to ensure public safety, fire and smoke control, and safe egress.

(3)

A building official may accept an alternate method, a modification, or waiver of other code items pertaining to the conversion of existing single-family dwellings into no more than four dwelling units. However, consistent with the discretionary decision making powers granted to building officials, and consistent with this rule, a building official may not approve a condition that would create an imminent threat to public health and safety.

(4)

Applicable standards for the conversion of a single-family dwelling as follows:

(a)

A conversion into two dwelling units follows the construction standards of the Oregon Residential Specialty Code; and

(b)

A conversion into three or four dwelling units follows the construction standards of the Oregon Structural Specialty Code.

Source: Rule 918-020-0390 — Alternative Approval Process for Single-Family Dwelling Conversions, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=918-020-0390.

918‑020‑0010
Relationship of Delegation Rules to Statute
918‑020‑0015
Definitions
918‑020‑0020
Cooperation with Other Agencies
918‑020‑0070
Purpose and Scope
918‑020‑0080
Delegation of Building Inspection Programs
918‑020‑0090
Program Standards
918‑020‑0091
Citation Process for Licensing Violations
918‑020‑0094
Program Assumption for State-Administered Jurisdictions
918‑020‑0095
Program Assumption Procedures
918‑020‑0105
Renewal of Existing Programs
918‑020‑0180
Reporting Periods
918‑020‑0190
Program Review
918‑020‑0200
Review Procedures
918‑020‑0210
Nonconformance Notice and Program Revocation
918‑020‑0220
Fee Adoption Standards
918‑020‑0370
Local Amendment Requests
918‑020‑0380
Electric Vehicle Ready Parking
918‑020‑0390
Alternative Approval Process for Single-Family Dwelling Conversions
918‑020‑0400
Statewide Master Builder Program — Application, Scope and Purpose
918‑020‑0410
Statewide Master Builder Program — Definitions
918‑020‑0420
Statewide Master Builder Program — Training and Experience Required of an Individual
918‑020‑0430
Voluntary Establishment of a Master Builder Program
918‑020‑0440
Statewide Master Builder Program — Inspection Requirements that May Be Waived
918‑020‑0450
Statewide Master Builder Program — Criteria to Waive Inspections or Plan Review
918‑020‑0460
Statewide Master Builder Program — Verification Requirements
918‑020‑0470
Statewide Master Builder Program — Assumption of Responsibility
918‑020‑0480
Statewide Master Builder Program — Revocation of Waiver
918‑020‑0490
Statewide Master Builder Program — Effective Dates
Last Updated

Jun. 8, 2021

Rule 918-020-0390’s source at or​.us