OAR 257-100-0010
Ignition Interlock Device Standards and Requirements


(1) Any device model for use in Oregon must meet the established standards set by OSP. OSP qualifies a device model for use in the state of Oregon based on its ability to meet the established device standards set forth by ORS 813.599 (Definitions), 813.600 (Ignition interlock program) and OAR 257-100-0010 (Ignition Interlock Device Standards and Requirements).
(2) To meet the device standards required for OSP to place a device on the list of qualified devices for use in the state of Oregon, the manufacturer’s representative must submit all of the following to OSP:
(a) A completed OSP Form 257-0001 - Application for Ignition Interlock Device Qualification.
(b) A written statement from the manufacturer on the manufacturer’s letterhead addressed to OSP that authorizes a manufacturer’s representative to act as the sole source manufacturer’s representative for the manufacturer’s device model.
(c) A certificate of insurance as proof of product liability insurance as described in OAR 257-100-0015 (Product Liability for Ignition Interlock Devices).
(d) Written documentation, issued within the preceding five years prior to submission of the application, from an International Organization for Standardization (ISO) 17025 certified testing laboratory that states that the device meets or exceeds the model specifications established by NHTSA, identified as “Model Specifications for Breath Alcohol Ignition Interlock Devices (BAIIDS).” The documentation must be for the manufacturer’s specific model of ignition interlock device listed on the application. The NHTSA model specification for BAIIDs is incorporated by reference and made part of this rule as published in the 78 FR 26849-26867 effective May 8, 2014 and 80 FR 16720-16723, effective March 30, 2015. The documentation from the ISO 17025 certified testing laboratory must include:
(A) The name, physical location, mailing address, and phone number of the testing laboratory;
(B) A description of the tests performed;
(C) Copies of the data and results of the testing procedures; and
(D) The names of the lab employees performing the tests.
(e) Written documentation of the manufacturer’s certification to the current International Organization for Standardization (ISO) 9001 Quality Management System (QMS) for aspects related to construction, production and repair of a device. Along with this certification, a copy of the manufacturer’s Quality Assurance Plan (QAP) for checking the accuracy of the calibration;
(A) All existing state certified manufacturer’s representatives shall apply for an accredited ISO 9001 certification no later than July 1, 2020, and successfully obtained by January 1, 2021. All new manufacturer’s representatives applying for certification shall obtain an accredited ISO 9001 certification prior to application submission to OSP.
(f) The ISO 9001 certified device being submitted for qualification;
(g) Any electronic device which reports login procedures, and allows online accessibility for OSP to review and download reports of any individual and device;
(h) A written notice to OSP, illustrating an implementation plan and description of any modification to the device. Any modification in either firmware or hardware may require the applicant to resubmit their device and all documents required in OAR 257-100-0010 (Ignition Interlock Device Standards and Requirements); and
(i) A signed OSP Ignition Interlock Device Violation Policy form (257-0012), detailing how the validity of violations committed by the individual will be determined in accordance with ORS 813.635 (Consequence for negative reports generated from ignition interlock device).
(3) Any time the manufacturer modifies the firmware or hardware of their approved device model, the device manufacturer or manufacturer’s representative must, as determined by OSP, either modify the device in OSP’s possession or send the modified device to OSP. OSP may test the device to determine if the device model, as modified, meets the standards described in OAR 257-100-0010 (Ignition Interlock Device Standards and Requirements).
(4) Applications for device qualification shall be resubmitted every five years.
[Publications: Publications referenced are available from OSP.]

Source: Rule 257-100-0010 — Ignition Interlock Device Standards and Requirements, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=257-100-0010.

Last Updated

Jun. 8, 2021