OAR 333-061-0074
Cross Connection Training Programs, Course, and Instructor Requirements


(1)

In order to qualify as an Authority approved Cross Connection Specialist training program or facility or Backflow Assembly Tester training program or facility, the following requirements must be met:

(a)

The training program must keep permanent records on attendance and performance of each student that enrolls in a course;

(b)

The training program must submit the names of students who have successfully completed the training course to the Authority upon completion of the training course;

(c)

The training schedule must be set in advance and the schedule must be submitted to the Authority quarterly for review and publication;

(d)

The backflow training program must maintain a proper ratio of student-to-training equipment. A maximum ratio of three students for each backflow assembly test station is allowed for the Backflow Assembly Tester-training course;

(e)

The training program must provide uniform training at all course locations;

(f)

The training program shall provide the training materials necessary to complete the course. The training materials must be updated annually and submitted to the Authority for approval; and

(g)

The training program must have the following minimum training equipment available for each course:

(A)

Each test station for Backflow Assembly Tester initial training and certification renewal courses shall include:
(i)
An operating PVB, SVB, double check valve backflow prevention assembly, and a RP, with appropriate test gauges for each assembly; and
(ii)
A backflow prevention assembly failure simulator shall also be provided that is capable of simulating leaking check valves, shutoff valves, and relief valve failures.

(B)

The training aids for the Backflow Assembly Tester training program or facility and Cross Connection Specialist training program or facility shall include the atmospheric vacuum breaker, PVB, SVB, double check valve backflow prevention assembly, RP, and a variety of test gauges.

(h)

The training program must maintain uniform course curriculum according to sections (2), (3), (4) and (5) of this rule section, and maintain uniform instructor requirements according to section (6) of this rule section, subject to approval by the Authority.

(2)

Requirements for the Cross Connection Specialist initial training course shall include:

(a)

A minimum of 30 hours of training;

(b)

The course content shall contain, but is not limited to, the following topics:

(A)

Definitions, identification of cross connection hazards, and the hydraulics of backflow;

(B)

Approved cross connection control methods, backflow prevention assembly specifications, and testing methods used for Authority-approved backflow prevention assemblies;

(C)

Cross connection control requirements for public water systems, implementation of a cross connection control program, and writing a local cross connection control ordinance;

(D)

Public education and record keeping requirements for an effective cross connection control program;

(E)

Facility water use inspection techniques and hands on inspection of local facilities to identify actual or potential cross connections;

(F)

Cross connection control program enforcement and managing a Backflow Assembly Tester program; and

(G)

Review and discussion of Cross Connection Specialist safety issues.

(c)

A minimum score of 70 percent is required to pass the Authority approved Cross Connection Specialist written examination.

(3)

Requirements for the Backflow Assembly Tester initial training course shall include:

(a)

A minimum of 40 hours of training;

(b)

The course content shall contain, but is not limited to, the following topics:

(A)

Definitions, identification of cross connections, and the hydraulics of backflow;

(B)

Hazards associated with backflow pollution and contamination of potable water, approved cross connection control methods, and cross connection control program requirements for public water systems;

(C)

Backflow prevention assembly approval requirements, specifications and installation requirements for approved backflow prevention assemblies, and backflow prevention assembly repair techniques;

(D)

Complete disassembly and reassembly of each type of backflow prevention assembly;

(E)

Hands-on demonstration of the correct test procedures, troubleshooting for each type of backflow prevention assembly, and diagnosis of two failure or abnormal conditions during the hands- on backflow assembly test of each type of backflow prevention assembly;

(F)

Test gauge calibration and gauge accuracy verification methods; and

(G)

Review and discussion of Backflow Assembly Tester safety issues.

(c)

A minimum score of 70 percent is required to pass the Authority-approved Backflow Assembly Tester written examination; and

(d)

A minimum score of 90 percent is required to pass the Authority-approved Backflow Assembly Tester physical performance examination.

(4)

Requirements for Cross Connection Specialist certification renewal shall include:

(a)

A minimum of 0.6 CEUs of training;

(b)

The course content shall contain, but is not limited to, the following topics:

(A)

Review of cross connection control regulations OAR 333-061-0070 (Cross Connection Control Requirements) through 0073;

(B)

Review and discussion of recent backflow incidents and identification of cross connections; and

(C)

Review and discussion of Cross Connection Specialist safety issues.

(5)

Requirements for Backflow Assembly Tester certification renewal shall include:

(a)

A minimum of 0.5 CEUs of training, excluding examination time;

(b)

The course content shall contain, but is not limited to, the following topics:

(A)

Review of cross connection control regulations OAR 333-061-0070 (Cross Connection Control Requirements) through 0073;

(B)

Review of approved test procedures for backflow prevention assemblies;

(C)

Hands-on demonstration of the correct test procedures for each type of backflow prevention assembly;

(D)

The correct student diagnosis and explanation of two failure or abnormal conditions during the hands-on backflow prevention assembly test of each type of backflow prevention assembly;

(E)

Review and discussion of Backflow Assembly Tester safety issues; and

(F)

Written examination that includes questions on cross connection control regulations OAR 333-061-0070 (Cross Connection Control Requirements) through 0073.

(c)

A minimum score of 70 percent is required to pass the Authority approved Backflow Assembly Tester written examination; and

(d)

A minimum score of 90 percent is required to pass the Authority approved Backflow Assembly Tester physical performance examination.

(6)

Instructor qualification requirements shall include:

(a)

To be eligible as an instructor for Cross Connection Specialist initial training or certification renewal course, the following experience in the cross connection control field is required:

(A)

Must be currently certified as a Cross Connection Specialist in Oregon;

(B)

Must have 2 years of experience in enforcement of cross connection control requirements, or as a certified Cross Connection Specialist, or have related experience, subject to approval by the Authority;

(C)

Must participate in two complete Cross Connection Specialist training courses as a student instructor assigned to teach a portion of the curriculum. A student instructor training program schedule must be submitted to the Authority for approval before training begins;

(D)

Must receive a recommendation from the instructor of record for approval as an instructor. An unfavorable recommendation must be documented by supporting information and may be challenged by the trainee or by the Authority; and

(E)

Must attend at least one instructor update meeting provided by the Authority each year.

(b)

To be eligible as an instructor for the Backflow Assembly Tester initial training or certification renewal course, the following experience in the backflow prevention field is required:

(A)

Must be currently certified as a Backflow Assembly Tester in Oregon;

(B)

Must have 2 years of experience as a certified Backflow Assembly Tester and experience installing, testing backflow prevention assemblies, or as a vocational instructor, or have related experience, subject to approval by the Authority;

(C)

Must participate in two complete Backflow Assembly Tester training courses as a student instructor assigned to teach a portion of the text curriculum and the physical performance portion of the curriculum. A student instructor training program schedule must be submitted to the Authority for approval before training begins;

(D)

Must receive a recommendation from the instructor of record for approval as an instructor. An unfavorable recommendation must be documented by supporting information and may be challenged by the trainee or by the Authority; and

(E)

Must attend at least one instructor update meeting provided by the Authority each year.

(c)

The Authority shall maintain a list of qualified instructors.

Source: Rule 333-061-0074 — Cross Connection Training Programs, Course, and Instructor Requirements, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-061-0074.

333‑061‑0005
Purpose
333‑061‑0010
Scope
333‑061‑0015
Adoption by Reference
333‑061‑0020
Definitions
333‑061‑0025
Responsibilities of Water Suppliers
333‑061‑0030
Maximum Contaminant Levels and Action Levels
333‑061‑0031
Maximum Residual Disinfectant Levels
333‑061‑0032
Treatment Requirements and Performance Standards for Surface Water, Groundwater Under Direct Influence of Surface Water, and Groundwater
333‑061‑0034
Treatment Requirements and Performance Standards for Corrosion Control
333‑061‑0036
Sampling and Analytical Requirements
333‑061‑0040
Reporting and Record Keeping
333‑061‑0042
Public Notice
333‑061‑0043
Consumer Confidence Reports
333‑061‑0045
Variances
333‑061‑0046
Permits
333‑061‑0050
Construction Standards
333‑061‑0055
Waivers from Construction Standards
333‑061‑0057
Voluntary Drinking Water Protection Program
333‑061‑0060
Plan Submission and Review Requirements
333‑061‑0061
Capacity Requirements for Public Water Systems
333‑061‑0062
Land Use Coordination
333‑061‑0063
Environmental Review Process for The Safe Drinking Water Revolving Loan Fund Program
333‑061‑0064
Emergency Response Plan Requirements
333‑061‑0065
Operation and Maintenance
333‑061‑0070
Cross Connection Control Requirements
333‑061‑0071
Backflow Prevention Assembly Installation and Operation Standards
333‑061‑0072
Backflow Assembly Tester Certification
333‑061‑0073
Cross Connection Specialist Certification
333‑061‑0074
Cross Connection Training Programs, Course, and Instructor Requirements
333‑061‑0075
Sanitary Surveys of Watersheds
333‑061‑0076
Sanitary Surveys
333‑061‑0077
Composite Correction Program & Comprehensive Performance Evaluations
333‑061‑0078
Coliform Investigations
333‑061‑0080
Role of Counties
333‑061‑0085
Supplemental Fluoridation
333‑061‑0087
Product Acceptability Criteria
333‑061‑0089
Annual Water System Fee
333‑061‑0090
Penalties
333‑061‑0095
Severability
333‑061‑0097
Adverse Health Effects Language
333‑061‑0098
References
333‑061‑0210
Operator Certification: Scope
333‑061‑0220
Classification of Water Treatment Plants and Water Distribution Systems
333‑061‑0225
General Requirements Applying to Water Suppliers and Water Systems
333‑061‑0228
Certification Requirements for Small Water System Operators
333‑061‑0230
Contracting For Services
333‑061‑0232
General Requirements Applying to Water System Operators
333‑061‑0235
Operator Certification Requirements, Levels 1–4
333‑061‑0245
Applications for Certification Levels 1–4
333‑061‑0250
Examinations for Certification, Levels 1–4
333‑061‑0260
Certificate Renewal Levels 1–4
333‑061‑0265
Fees
333‑061‑0270
Refusal, Suspension, or Revocation of Certification
333‑061‑0272
Suspension of Certification
333‑061‑0305
Domestic Well Program: Purpose
333‑061‑0310
Scope
333‑061‑0324
Area of Public Health Concern
333‑061‑0325
Domestic Well Tests
333‑061‑0330
Accredited Laboratories
333‑061‑0335
Sample Collection
333‑061‑0400
Reducing Lead in School Drinking Water
333‑061‑0510
Applicability of Cyanotoxin Rules
333‑061‑0520
Definitions
333‑061‑0530
Health Advisory Levels
333‑061‑0540
Cyanotoxin Monitoring
333‑061‑0550
Analytical Methods
333‑061‑0560
Reporting
333‑061‑0570
Public Notification
333‑061‑0580
Record Keeping
Last Updated

Jun. 8, 2021

Rule 333-061-0074’s source at or​.us