OAR 333-061-0510
Applicability of Cyanotoxin Rules


(1) Water suppliers are subject to OAR 333-061-0510 (Applicability of Cyanotoxin Rules) to 333-061-0580 (Record Keeping) when they own or operate water systems that:
(a) Are supplied by a surface water source that is determined by the Authority to be susceptible to harmful algal blooms or release of cyanotoxins; or
(b) Are supplied by a groundwater source determined by the Authority to be under the direct influence of a surface water source that is susceptible to harmful algal blooms or release of cyanotoxins; or
(c) Purchase water from another water system that is supplied by a surface water source or a groundwater source determined by the Authority under the direct influence of a surface water that is susceptible to harmful algal blooms or release of cyanotoxins.
(2) A water source is susceptible to harmful algal blooms or release of cyanotoxins if:
(a) One or more harmful algal blooms have been documented or at least one cyanotoxin was previously detected in the water source or other location in a public water system supplied by that water source;
(b) The source or a waterbody upstream of the source is listed in the Oregon DEQ Integrated Report and Clean Water Act Section 303(d) list for not meeting water quality standards for algae and aquatic weeds;
(c) The point of diversion into the water system is downstream of or influenced by another surface water source susceptible to harmful algal blooms or release of cyanotoxins; or
(d) The Authority determines the source is susceptible based on the characteristics of the source, including, but not limited to, slow moving or stagnant water, temperature, available sources of nutrients, water quality data, satellite imagery, presence of microcystin- or cylindrospermopsin-producing genes, or other relevant information.
(3) The Authority may, at its discretion, exempt a water supplier that would otherwise be subject to OAR 333-061-0510 (Applicability of Cyanotoxin Rules) to 333-061-0580 (Record Keeping) if the Authority determines that the water source is not likely to be susceptible to cyanotoxins based on information available to the Authority or based on evidence submitted by the water supplier that includes but is not limited to, water quality data, watershed characteristics, and environmental conditions.

Source: Rule 333-061-0510 — Applicability of Cyanotoxin Rules, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-061-0510.

333–061–0005
Purpose
333–061–0010
Scope
333–061–0015
Adoption by Reference
333–061–0020
Definitions
333–061–0025
Responsibilities of Water Suppliers
333–061–0030
Maximum Contaminant Levels and Action Levels
333–061–0031
Maximum Residual Disinfectant Levels
333–061–0032
Treatment Requirements and Performance Standards for Surface Water, Groundwater Under Direct Influence of Surface Water, and Groundwater
333–061–0034
Treatment Requirements and Performance Standards for Corrosion Control
333–061–0036
Sampling and Analytical Requirements
333–061–0040
Reporting and Record Keeping
333–061–0042
Public Notice
333–061–0043
Consumer Confidence Reports
333–061–0045
Variances
333–061–0046
Permits
333–061–0050
Construction Standards
333–061–0055
Waivers from Construction Standards
333–061–0057
Voluntary Drinking Water Protection Program
333–061–0060
Plan Submission and Review Requirements
333–061–0061
Capacity Requirements for Public Water Systems
333–061–0062
Land Use Coordination
333–061–0063
Environmental Review Process for The Safe Drinking Water Revolving Loan Fund Program
333–061–0064
Emergency Response Plan Requirements
333–061–0065
Operation and Maintenance
333–061–0070
Cross Connection Control Requirements
333–061–0071
Backflow Prevention Assembly Installation and Operation Standards
333–061–0072
Backflow Assembly Tester Certification
333–061–0073
Cross Connection Specialist Certification
333–061–0074
Cross Connection Training Programs, Course, and Instructor Requirements
333–061–0075
Sanitary Surveys of Watersheds
333–061–0076
Sanitary Surveys
333–061–0077
Composite Correction Program & Comprehensive Performance Evaluations
333–061–0078
Coliform Investigations
333–061–0080
Role of Counties
333–061–0085
Supplemental Fluoridation
333–061–0087
Product Acceptability Criteria
333–061–0089
Annual Water System Fee
333–061–0090
Penalties
333–061–0095
Severability
333–061–0097
Adverse Health Effects Language
333–061–0098
References
333–061–0210
Operator Certification: Scope
333–061–0220
Classification of Water Treatment Plants and Water Distribution Systems
333–061–0225
General Requirements Applying to Water Suppliers and Water Systems
333–061–0228
Certification Requirements for Small Water System Operators
333–061–0230
Contracting For Services
333–061–0232
General Requirements Applying to Water System Operators
333–061–0235
Operator Certification Requirements, Levels 1–4
333–061–0245
Applications for Certification Levels 1–4
333–061–0250
Examinations for Certification, Levels 1–4
333–061–0260
Certificate Renewal Levels 1–4
333–061–0265
Fees
333–061–0270
Refusal, Suspension, or Revocation of Certification
333–061–0272
Suspension of Certification
333–061–0305
Domestic Well Program: Purpose
333–061–0310
Scope
333–061–0324
Area of Public Health Concern
333–061–0325
Domestic Well Tests
333–061–0330
Accredited Laboratories
333–061–0335
Sample Collection
333–061–0400
Reducing Lead in School Drinking Water
333–061–0510
Applicability of Cyanotoxin Rules
333–061–0520
Definitions
333–061–0530
Health Advisory Levels
333–061–0540
Cyanotoxin Monitoring
333–061–0550
Analytical Methods
333–061–0560
Reporting
333–061–0570
Public Notification
333–061–0580
Record Keeping
Last Updated

Jun. 8, 2021

Rule 333-061-0510’s source at or​.us