OAR 918-282-0050
Limited Maintenance Specialty Contractor License


(1)

A limited maintenance specialty contractor:

(a)

May connect replacement appliances to existing junction boxes;

(b)

May repair by replacement, as defined in OAR 918-251-0090 (Board-Created Definitions), ballasts, lamp holders and equipment that are a part of lighting fixtures; and

(c)

Shall not make electrical installations involving services, feeders or branch circuits.

(2)

A firm that holds a valid limited maintenance specialty contractor license shall provide and maintain a list of employees in accordance with ORS 479.630 (Requirements for obtaining licenses) and shall designate to the division an individual within the firm who shall be responsible for compliance with applicable codes and rules for obtaining permits and calling for inspections.

(3)

The applicant shall provide verification of one year of experience in appliance repair or replacement work as defined in statute.

(4)

This contractor can convert to a limited maintenance specialty contractor-HVAC/R by meeting the requirements of OAR 918-282-0040 (Limited Maintenance Specialty Contractor-HVAC/R License) and paying an additional fee.

(5)

Limited maintenance specialty contractor employees need not be licensed.

Source: Rule 918-282-0050 — Limited Maintenance Specialty Contractor License, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=918-282-0050.

918–282–0000
Electrical Contractors in General
918–282–0010
Electrical Contractor License
918–282–0015
Electrical Contractor’s Responsibilities
918–282–0017
Elevator Contractor Electrical License
918–282–0020
Limited Sign Contractor License
918–282–0030
Limited Energy Contractor License
918–282–0033
Limited Renewable Energy Contractor
918–282–0040
Limited Maintenance Specialty Contractor-HVAC/R License
918–282–0050
Limited Maintenance Specialty Contractor License
918–282–0060
Restricted Energy Contractor License
918–282–0070
Limited Pump Installation Specialty Contractor License
918–282–0100
Electrical Licensing in General
918–282–0110
General Licensing Exemptions
918–282–0120
Licensing Requirements for Electrical Work
918–282–0130
Fees
918–282–0140
General Supervising Electrician License
918–282–0150
Employment Requirements for Supervising Electricians Employed by Industrial or Manufacturing Plant
918–282–0160
Limited Supervising Electrician License
918–282–0170
General Journeyman License
918–282–0180
Limited Residential Electrician License
918–282–0185
Limited Elevator Journeyman License
918–282–0190
Limited Journeyman Manufacturing Plant Electrician License
918–282–0200
Indorsement for Manufacturing Plant Electricians
918–282–0205
Limited Renewable Energy Technician
918–282–0220
Limited Journeyman Sign Electrician License
918–282–0230
Limited Journeyman Stage Electrician License
918–282–0240
Limited Maintenance Electrician License
918–282–0260
Limited Building Maintenance Electrician License
918–282–0270
Apprentices
918–282–0290
Elevator Apprenticeship Program
918–282–0345
Class “A” Limited Energy Technician License
918–282–0355
Licensing Requirements for Class “A” Limited Energy Technician
918–282–0360
Class “B” Limited Energy Technician
918–282–0365
Licensing Requirements for Class “B” Limited Energy Technician
918–282–0400
Solar Licensing
Last Updated

Jun. 8, 2021

Rule 918-282-0050’s source at or​.us