OAR 333-060-0085
Diving


(1)

Public swimming pools used for diving shall provide water depths and lateral and vertical clearances as follows:

(a)

Pools constructed after May 1, 1986, shall comply with the minimum dimensions of Figure 1, Table 1. [Table not included. See ED. Note.]

(b)

Pools constructed prior to May 1, 1986, shall comply with the minimum dimensions of Figure 2, Table 2. [Table not included. See ED. Note.]

(2)

There shall be at least 16’ (4.9m) of unobstructed vertical clearance above any diving board measured from the center of the front end of the board. This clearance shall extend horizontally 8’ (2.4m) behind, 16’ (4.9m) in front, and 8’ (2.4m) to each side of the end of the board.

(3)

Intentionally left blank —Ed.

(a)

Diving boards one meter or more in height above the water shall be equipped with a stairway or ladder and two handrails;

(b)

Diving boards one meter or higher shall be protected with guard rails, one on each side of the board. Such guard rails shall extend to the edge of the pool wall.

(4)

Diving platforms higher than three meters shall not be installed at public swimming pools without the approval of the Division.
[ED. NOTE: Tables referenced are available from the agency.]
333‑060‑0005
Purpose
333‑060‑0010
Adoption by Reference
333‑060‑0015
Definitions
333‑060‑0020
Compliance
333‑060‑0025
Approval to Construct
333‑060‑0030
Plans
333‑060‑0035
Licenses
333‑060‑0040
Conditional Licenses
333‑060‑0045
Maintenance and Modification
333‑060‑0050
Structural Stability
333‑060‑0055
Size
333‑060‑0060
Dimensions
333‑060‑0065
Finishes, Markings and Lifelines
333‑060‑0070
Illumination
333‑060‑0075
Ventilation
333‑060‑0080
Ladders, Recessed Steps and Stairways
333‑060‑0085
Diving
333‑060‑0090
Slides
333‑060‑0091
Waterpark Slides
333‑060‑0095
Elevated Lifeguard Chairs
333‑060‑0100
Life Saving Equipment
333‑060‑0105
Swimming Pool Enclosure
333‑060‑0110
Decks
333‑060‑0115
Overflow Systems
333‑060‑0120
Recirculation System
333‑060‑0125
Inlets
333‑060‑0128
Submerged Suction Outlets and Drains
333‑060‑0130
Piping
333‑060‑0135
Pumps
333‑060‑0140
Filters
333‑060‑0145
Pool Heaters
333‑060‑0150
Disinfectant and Chemical Feeders
333‑060‑0155
Meters and Gauges
333‑060‑0160
Equipment Room
333‑060‑0165
Ground Fault Interrupter
333‑060‑0170
Bathhouses and Sanitary Facilities
333‑060‑0175
Visitor and Spectator Areas
333‑060‑0180
Food Service
333‑060‑0185
Drinking Fountains
333‑060‑0190
Domestic Water Quality
333‑060‑0200
Pool Water Quality
333‑060‑0205
Operation and Maintenance
333‑060‑0206
Supervision — Limited-Use Pools
333‑060‑0207
Supervision — General-Use Pools
333‑060‑0208
Lifeguard Supervision & Training
333‑060‑0209
Pool Staff Training & Safety
333‑060‑0210
Pool Safety
333‑060‑0215
Signs
333‑060‑0220
Variance
333‑060‑0225
Instructional Use of Limited-Use Pools
333‑060‑0500
Wading Pools
333‑060‑0505
New Wading Pool Construction
333‑060‑0510
Existing Wading Pools
333‑060‑0515
Wading Pool Operation
333‑060‑0700
Enforcement
333‑060‑0705
Pool Closure Criteria
Last Updated

Jun. 8, 2021

Rule 333-060-0085’s source at or​.us