OAR 333-122-0130
General Requirements for all RGD: Operating Requirements


(1) Procedures. Normal operating procedures shall be written and available to all X-ray operators. No individual shall be permitted to operate X-ray equipment in any manner other than that specified in the procedures unless the individual has obtained written approval from the radiation safety officer.
(a) No individual shall hold in their hands, or have on their bodies, the object analyzed by an X-ray machine during the radiation exposure process.
(b) Each individual shall maintain the proper forward positioning of a hand-held X-ray unit during the radiation exposure process.
(c) A hand-held X-ray machine may be utilized in an appropriate container, testing tower, or protective device as described in the manufacturer’s specifications.
(2) Bypassing. No individual shall bypass a safety device or interlock unless the individual has obtained approval from the radiation safety officer.
(a) The approval to bypass shall be for a specified period of time.
(b) When a safety device or interlock has been bypassed, a readily discernible sign bearing the words, SAFETY DEVICE NOT WORKING, or words having a similar intent, shall be placed on the radiation source housing.
(3) Repair or Modification of X-ray Tube Systems. Except as specified in OAR 333-108-0115(2), no operation involving removal of covers, shielding materials or tube housings, modifications to shutters, collimators or beam stops shall be performed without ascertaining that the tube is off and will remain off until safe conditions have been restored. The main switch, rather than interlocks, shall be used for routine shutdown in preparation for repairs.

Source: Rule 333-122-0130 — General Requirements for all RGD: Operating Requirements, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-122-0130.

333‑122‑0001
Purpose
333‑122‑0003
Scope
333‑122‑0005
Definitions
333‑122‑0010
General Requirements for All RGD: Radiation Safety Officer
333‑122‑0020
General Requirements for All RGD: Safety Device
333‑122‑0030
General Requirements for All RGD: Warning Devices
333‑122‑0040
General Requirements for All RGD: Ports
333‑122‑0050
Exemptions
333‑122‑0055
General Requirements for All RGD: Labeling
333‑122‑0060
General Requirements for All RGD: Shutters
333‑122‑0065
General Requirements for All RGD: X-ray Tube Registration
333‑122‑0070
General Requirements for All RGD: Warning Lights
333‑122‑0076
General Requirements for All RGD: and Radiation Source Housing Requirements
333‑122‑0090
General Requirements for All RGD: Generator Cabinet
333‑122‑0101
General Requirements for All RGD: Radiation Levels
333‑122‑0110
General Requirements for All RGD: Surveys
333‑122‑0120
General Requirements for All RGD: Posting.
333‑122‑0130
General Requirements for all RGD: Operating Requirements
333‑122‑0140
General Requirements for All RGD: Operating and Emergency Procedures
333‑122‑0151
General Requirements for All RGD: Copies of Operating and Emergency Procedures
333‑122‑0160
General Requirements for All RGD: Training
333‑122‑0170
General Requirements for All RGD: Records of Training and Certification
333‑122‑0180
General Requirements for All RGD: Individual Monitoring
333‑122‑0190
General Requirements for All RGD: Dosimetry Individual Monitoring
333‑122‑0201
General Requirements for All RGD: Records of Personnel Monitoring
333‑122‑0210
General Requirements for All RGD: Records of Personnel Monitoring
333‑122‑0226
General Requirements for All RGD: Records of Radiation Survey Instruments
333‑122‑0230
General Requirements for All RGD: Inspection and Maintenance of RGD X-ray Machines, Associated Equipment, and Survey Instruments
333‑122‑0240
Records of Inspection and Maintenance of RGD, Associated Equipment, and Survey
333‑122‑0251
General Requirements for All RGD: Form of Records ​​​​​​​
333‑122‑0260
General Requirements for All RGD: Recordkeeping Requirements for RGD X-Ray
333‑122‑0270
General Requirements for All RGD: Location of Documents and Records
333‑122‑0276
X-ray and Hybrid Gauges: Safety Device
333‑122‑0280
X-ray and Hybrid Gauges: Warning Signs
333‑122‑0290
X-ray and Hybrid Gauges: Security
333‑122‑0301
X-ray and Hybrid Gauges: Surveys
333‑122‑0310
X-ray and Hybrid Gauges: Surveillance
333‑122‑0320
Permanent X-ray Radiography Installations
333‑122‑0326
Permanent X-ray Radiography Installations: Records of Alarm System and Entrance Control Checks
333‑122‑0380
Whole Body Imagers: Appropriate Uses
333‑122‑0600
Notifications
Last Updated

Jun. 8, 2021

Rule 333-122-0130’s source at or​.us