OAR 333-122-0190
General Requirements for All RGD: Dosimetry Individual Monitoring


When required by the Authority:
(1) The registrant may not permit any individual to act as a X-ray operator unless, at all times during radiographic operations, each X-ray operator wears, on the trunk of the body, a combination of direct reading dosimeter, and either a film badge, optically stimulated luminescence (OSL) or a thermoluminescent dosimeter (TLD) or other National Voluntary Laboratory Accreditation Program (NVLAP) approved technologies. X-ray operators who only operate cabinet X-ray machines are exempt from the requirement to wear a direct reading dosimeter.
(a) Pocket dosimeters must have a range from zero to 2 milliseiverts (200 mrem) and must be recharged at the start of each shift. Electronic personal dosimeters may only be used in place of ion-chamber pocket dosimeters.
(b) Each radiation dose measuring device must be assigned to and worn by only one individual.
(c) Radiation dose measuring devices must be exchanged at periods not to exceed quarterly.
(d) After replacement, each dose measuring device must be returned to the supplier for processing within 14 calendar days of the end of the monitoring period, or as soon as practicable. In circumstances that make it impossible to return each dose measuring device in 14 calendar days, such circumstances must be documented and available for review by the Authority.
(2) Direct reading dosimeters such as pocket dosimeters or electronic personal dosimeters, must be read and the exposures recorded at the beginning and end of each shift, and records must be maintained in accordance with OAR 333-122-0201 (General Requirements for All RGD: Records of Personnel Monitoring).
(3) Pocket dosimeters, or electronic personal dosimeters, must be checked at periods not to exceed 12 months for correct response to radiation, and records must be maintained in accordance with OAR 333-122-0201 (General Requirements for All RGD: Records of Personnel Monitoring). Acceptable dosimeters must read within plus or minus 20 percent of the true radiation exposure.
(4) If an individual’s pocket dosimeter is found to be beyond the visible scale demarcation, or the electronic personal dosimeter reads greater than 2 milliseiverts (200 mrem), the individual’s dose measuring device must be sent for processing within 24 hours.
(a) The individual may not resume work associated with the use of sources of radiation until a determination of the individual’s radiation exposure has been made. This determination must be made by the radiation safety officer or the radiation safety officer’s designee.
(b) The results of this determination must be included in the records maintained in accordance with OAR 333-122-0201 (General Requirements for All RGD: Records of Personnel Monitoring).
(5) If a radiation dose measuring device is lost or damaged, the worker must cease work immediately until a replacement radiation dose measuring device is provided and the exposure is calculated for the period from issuance to loss or damage of the dose measuring device. The results of the calculated exposure and the period for which the radiation dose measuring device was lost or damaged must be included in the records maintained in accordance with OAR 333-122-0201 (General Requirements for All RGD: Records of Personnel Monitoring).
(6) Reports received from the radiation dose measuring device processor must be retained in accordance with OAR 333-122-0201 (General Requirements for All RGD: Records of Personnel Monitoring).
(7) Finger or wrist dosimetry devices shall be provided to and shall be used by all personnel working with open beam gauging equipment.

Source: Rule 333-122-0190 — General Requirements for All RGD: Dosimetry Individual Monitoring, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-122-0190.

333‑122‑0001
Purpose
333‑122‑0003
Scope
333‑122‑0005
Definitions
333‑122‑0010
General Requirements for All RGD: Radiation Safety Officer
333‑122‑0020
General Requirements for All RGD: Safety Device
333‑122‑0030
General Requirements for All RGD: Warning Devices
333‑122‑0040
General Requirements for All RGD: Ports
333‑122‑0050
Exemptions
333‑122‑0055
General Requirements for All RGD: Labeling
333‑122‑0060
General Requirements for All RGD: Shutters
333‑122‑0065
General Requirements for All RGD: X-ray Tube Registration
333‑122‑0070
General Requirements for All RGD: Warning Lights
333‑122‑0076
General Requirements for All RGD: and Radiation Source Housing Requirements
333‑122‑0090
General Requirements for All RGD: Generator Cabinet
333‑122‑0101
General Requirements for All RGD: Radiation Levels
333‑122‑0110
General Requirements for All RGD: Surveys
333‑122‑0120
General Requirements for All RGD: Posting.
333‑122‑0130
General Requirements for all RGD: Operating Requirements
333‑122‑0140
General Requirements for All RGD: Operating and Emergency Procedures
333‑122‑0151
General Requirements for All RGD: Copies of Operating and Emergency Procedures
333‑122‑0160
General Requirements for All RGD: Training
333‑122‑0170
General Requirements for All RGD: Records of Training and Certification
333‑122‑0180
General Requirements for All RGD: Individual Monitoring
333‑122‑0190
General Requirements for All RGD: Dosimetry Individual Monitoring
333‑122‑0201
General Requirements for All RGD: Records of Personnel Monitoring
333‑122‑0210
General Requirements for All RGD: Records of Personnel Monitoring
333‑122‑0226
General Requirements for All RGD: Records of Radiation Survey Instruments
333‑122‑0230
General Requirements for All RGD: Inspection and Maintenance of RGD X-ray Machines, Associated Equipment, and Survey Instruments
333‑122‑0240
Records of Inspection and Maintenance of RGD, Associated Equipment, and Survey
333‑122‑0251
General Requirements for All RGD: Form of Records ​​​​​​​
333‑122‑0260
General Requirements for All RGD: Recordkeeping Requirements for RGD X-Ray
333‑122‑0270
General Requirements for All RGD: Location of Documents and Records
333‑122‑0276
X-ray and Hybrid Gauges: Safety Device
333‑122‑0280
X-ray and Hybrid Gauges: Warning Signs
333‑122‑0290
X-ray and Hybrid Gauges: Security
333‑122‑0301
X-ray and Hybrid Gauges: Surveys
333‑122‑0310
X-ray and Hybrid Gauges: Surveillance
333‑122‑0320
Permanent X-ray Radiography Installations
333‑122‑0326
Permanent X-ray Radiography Installations: Records of Alarm System and Entrance Control Checks
333‑122‑0380
Whole Body Imagers: Appropriate Uses
333‑122‑0600
Notifications
Last Updated

Jun. 8, 2021

Rule 333-122-0190’s source at or​.us