OAR 333-122-0180
General Requirements for All RGD: Individual Monitoring


(1) Finger or wrist dosimetry devices shall be provided and used by:
(a) RGD X-ray operators using systems having an open-beam configuration and not equipped with a safety device; and
(b) Personnel maintaining RGD X-ray equipment if the maintenance procedures require the presence of a primary X-ray beam when any local component in the X-ray system is disassembled or removed.
(2) Operators will be exempt from the requirements of this rule, if the following criteria are met:
(a) The RGD X-ray machine shielding meets the requirements in OAR 333-122-0090 (General Requirements for All RGD: Generator Cabinet), or
(b) The RGD X-ray machine is classified as an XRF analytical hand-held device and meets the requirements in OAR 333-122-0020 (General Requirements for All RGD: Safety Device); or
(c) The registrant provides calculations and documentation of operator exposures during maximum usage over the course of normal operations (2080 hours per year) that are less than or equal to 500 mR per year per operator and not exceed any limits listed in OAR 333-120-0100 (Radiation Dose Limits: Occupational Dose Limits For Adults).
(3) Reported dose values from measured X-ray operator exposures shall not be used for the purpose of determining compliance with OAR 333-120-0100 (Radiation Dose Limits: Occupational Dose Limits For Adults) unless evaluated by a qualified expert.

Source: Rule 333-122-0180 — General Requirements for All RGD: Individual Monitoring, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-122-0180.

333‑122‑0001
Purpose
333‑122‑0003
Scope
333‑122‑0005
Definitions
333‑122‑0010
General Requirements for All RGD: Radiation Safety Officer
333‑122‑0020
General Requirements for All RGD: Safety Device
333‑122‑0030
General Requirements for All RGD: Warning Devices
333‑122‑0040
General Requirements for All RGD: Ports
333‑122‑0050
Exemptions
333‑122‑0055
General Requirements for All RGD: Labeling
333‑122‑0060
General Requirements for All RGD: Shutters
333‑122‑0065
General Requirements for All RGD: X-ray Tube Registration
333‑122‑0070
General Requirements for All RGD: Warning Lights
333‑122‑0076
General Requirements for All RGD: and Radiation Source Housing Requirements
333‑122‑0090
General Requirements for All RGD: Generator Cabinet
333‑122‑0101
General Requirements for All RGD: Radiation Levels
333‑122‑0110
General Requirements for All RGD: Surveys
333‑122‑0120
General Requirements for All RGD: Posting.
333‑122‑0130
General Requirements for all RGD: Operating Requirements
333‑122‑0140
General Requirements for All RGD: Operating and Emergency Procedures
333‑122‑0151
General Requirements for All RGD: Copies of Operating and Emergency Procedures
333‑122‑0160
General Requirements for All RGD: Training
333‑122‑0170
General Requirements for All RGD: Records of Training and Certification
333‑122‑0180
General Requirements for All RGD: Individual Monitoring
333‑122‑0190
General Requirements for All RGD: Dosimetry Individual Monitoring
333‑122‑0201
General Requirements for All RGD: Records of Personnel Monitoring
333‑122‑0210
General Requirements for All RGD: Records of Personnel Monitoring
333‑122‑0226
General Requirements for All RGD: Records of Radiation Survey Instruments
333‑122‑0230
General Requirements for All RGD: Inspection and Maintenance of RGD X-ray Machines, Associated Equipment, and Survey Instruments
333‑122‑0240
Records of Inspection and Maintenance of RGD, Associated Equipment, and Survey
333‑122‑0251
General Requirements for All RGD: Form of Records ​​​​​​​
333‑122‑0260
General Requirements for All RGD: Recordkeeping Requirements for RGD X-Ray
333‑122‑0270
General Requirements for All RGD: Location of Documents and Records
333‑122‑0276
X-ray and Hybrid Gauges: Safety Device
333‑122‑0280
X-ray and Hybrid Gauges: Warning Signs
333‑122‑0290
X-ray and Hybrid Gauges: Security
333‑122‑0301
X-ray and Hybrid Gauges: Surveys
333‑122‑0310
X-ray and Hybrid Gauges: Surveillance
333‑122‑0320
Permanent X-ray Radiography Installations
333‑122‑0326
Permanent X-ray Radiography Installations: Records of Alarm System and Entrance Control Checks
333‑122‑0380
Whole Body Imagers: Appropriate Uses
333‑122‑0600
Notifications
Last Updated

Jun. 8, 2021

Rule 333-122-0180’s source at or​.us