OAR 333-062-0095
Recirculation Systems


(1)

Public spa pools shall have recirculation systems and filtration systems with piping, pumps, filters, disinfection and other equipment which maintain spa pool water quality in accordance with OAR 333-062-0165 (Spa Water Quality)(1).

(2)

The system of pumps, filters, disinfection facilities and other equipment shall be of adequate size to recirculate, filter and disinfect the entire volume of spa water within 30 minutes.

(3)

The recirculation system shall be a two pump system. One pump will provide the required turnover rate, filtration and disinfection for the spa water. The second pump shall provide the water for the hydrotherapy turbulence of the water.

(4)

Public spa pool recirculation systems shall be separate from companion swimming pools.

(5)

Recirculation and filtration systems shall be in operation continuously while the facility is in use.

Source: Rule 333-062-0095 — Recirculation Systems, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-062-0095.

Last Updated

Jun. 8, 2021

Rule 333-062-0095’s source at or​.us