OAR 333-062-0135
Valves, Meters, and Gauges


(1)

Flow meters shall be installed in all recirculation systems. Such meters shall:

(a)

Measure flow in gallons per minute;

(b)

Be mounted as recommended by the manufacturer; and

(c)

Be located so as to be easily read.

(2)

Pressure gauges shall be installed on the inlet and outlet of the filter.

(3)

When the pump is below the overflow rim of the spa, valves shall be installed on permanently connected suction and discharge lines and located in an accessible place outside the walls of the spa. All valves shall be located where they will be readily and easily accessible for maintenance and removal.