OAR 333-113-0145
Equipment Control: Inspection and Maintenance


(1)

Each licensee or registrant must conduct, at intervals not to exceed six months, a visual check of source holders, logging tools, source handling tools, storage containers, transport containers and injection tools to ensure proper labeling and physical condition. Records of inspection and maintenance must be maintained in accordance with 333-100-0057 (Maintenance of Records).

(2)

If any inspection conducted pursuant to section (1) of this rule reveals defects or damage to labeling or components, the device must be removed from service until repairs have been made.

(3)

If a sealed source is stuck in the source holder, the licensee must not perform any operation, such as drilling, cutting or chiseling, on the source holder unless the licensee is specifically approved by the U.S. Nuclear Regulatory Agency, an Agreement State or a Licensing State to perform this operation.

(4)

The repair, opening or modification of any sealed source must be performed only by persons specifically authorized to do so by the Authority, the U.S. Nuclear Regulatory Agency, an Agreement State or a Licensing State.

(5)

Removal of a sealed source from a source holder or logging tool, and maintenance on sealed sources or holders in which sealed sources are contained may not be performed by the licensee unless a written procedure has been developed and approved either by the Authority, the Nuclear Regulatory Agency or by an Agreement State or a Licensing State.

Source: Rule 333-113-0145 — Equipment Control: Inspection and Maintenance, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-113-0145.

333‑113‑0001
Purpose and Scope
333‑113‑0005
Definitions
333‑113‑0007
Specific Licenses For Well Logging
333‑113‑0010
Agreement With Well Owner of Operator
333‑113‑0101
Equipment Control: Limits on Levels of Radiation
333‑113‑0105
Equipment Control: Storage Precautions
333‑113‑0110
Equipment Control: Transport Precautions
333‑113‑0115
Equipment Control: Radiation Survey Instruments
333‑113‑0120
Equipment Control: Leak Testing of Sealed Sources
333‑113‑0125
Equipment Control: Physical Inventory
333‑113‑0130
Equipment Control: Utilization Records
333‑113‑0135
Equipment Control: Design, Performance and Certification Criteria for Sealed Sources
333‑113‑0140
Equipment Control: Labeling
333‑113‑0145
Equipment Control: Inspection and Maintenance
333‑113‑0150
Equipment Control: Use of a Sealed Source in a Well without a Surface Casing
333‑113‑0201
Requirements for Personnel Safety: Training Requirements
333‑113‑0203
Requirements for Personnel Safety: Subjects to be Included in Training Courses for Logging Supervisors
333‑113‑0205
Requirements for Personnel Safety: Operating and Emergency Procedures
333‑113‑0210
Requirements for Personnel Safety: Personnel Monitoring
333‑113‑0301
Precautionary Procedures in Logging and Subsurface Tracer Studies: Security
333‑113‑0305
Precautionary Procedures in Logging and Subsurface Tracer Studies: Handling Tools
333‑113‑0310
Precautionary Procedures in Logging and Subsurface Tracer Studies: Subsurface Tracer Studies
333‑113‑0315
Precautionary Procedures in Logging and Subsurface Tracer Studies: Particle Accelerators
333‑113‑0325
Precautionary Procedures in Logging and Subsurface Tracer Studies: Energy Compensation Source
333‑113‑0335
Precautionary Procedures in Logging and Subsurface Tracer Studies: Tritium Neutron Generator Target Source
333‑113‑0401
Radiation Surveys
333‑113‑0403
Radiation Surveys and Records: Radioactive Contamination Control
333‑113‑0405
Radiation Surveys and Records: Documents and Records Required at Field Stations
333‑113‑0410
Radiation Surveys and Records: Documents and Records Required at Temporary Jobsites
333‑113‑0501
Notification of Incidents, Abandonment and Lost Sources
Last Updated

Jun. 8, 2021

Rule 333-113-0145’s source at or​.us