OAR 333-121-0180
Power Failures


(1)

If electrical power at a panoramic irradiator is lost for longer than ten seconds, the sources must automatically return to the shielded position.

(2)

The lock on the door of the radiation room of a panoramic irradiator must remain locked in the event of a power failure.

(3)

During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.