OAR 333-121-0320
Personnel Monitoring


(1)

Irradiator operators must wear a personnel dosimeter that is processed and evaluated by an accredited National Voluntary Laboratory Accreditation Program (NVLAP) processor while operating a panoramic irradiator or while in the area around the pool of an underwater irradiator. The personnel dosimeter processor must be accredited by the National Voluntary Laboratory Accreditation Program for high energy photons in the normal and accident dose ranges, see 333-120-0200 (Surveys and Monitoring: General)(3). Each personnel dosimeter must be assigned to and worn by only one individual. Film badges must be processed at least monthly, and other personnel dosimeters must be processed at least quarterly.

(2)

Other individuals who enter the radiation room of a panoramic irradiator must wear a dosimeter, which may be a pocket dosimeter. For groups of visitors, only two people who enter the radiation room are required to wear dosimeters. If pocket dosimeters are used to meet the requirements of the paragraph, a check of their response to radiation must be done at least annually. Acceptable dosimeters must read within ±20% of the true radiation dose.

Source: Rule 333-121-0320 — Personnel Monitoring, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=333-121-0320.

Last Updated

Jun. 8, 2021

Rule 333-121-0320’s source at or​.us