OAR 340-240-0050
Compliance Testing Requirements
(1)
For demonstrating compliance with the standards in this division, testing must be done in accordance with the DEQ Source Sampling Manual.(2)
For demonstrating compliance with particulate standards, testing must be conducted using the following test methods, or alternative methods approved by DEQ:(a)
For wood waste boilers — DEQ Method 5. Results must be corrected to 12% CO2, as follows(A)
C(12% CO2) = C x 12/%CO2(B)
As used in paragraph (A):(b)
For veneer dryers, wood material dryers, press and other process vents — DEQ Method 7; and(c)
For air conveying systems — DEQ Method 5 or 8.(3)
For demonstrating compliance with opacity standards, observations must be made in accordance with EPA Method 9 or continuous opacity monitoring systems certified in accordance with the DEQ Continuous Monitoring Manual.
Source:
Rule 340-240-0050 — Compliance Testing Requirements, https://secure.sos.state.or.us/oard/view.action?ruleNumber=340-240-0050
.