OAR 340-240-0030
Definitions


The definitions in OAR 340-200-0020 (General Air Quality Definitions), 340-204-0010 (Definitions) and this rule apply to this division. If the same term is defined in this rule and 340-200-0020 (General Air Quality Definitions) or 340-204-0010 (Definitions), the definition in this rule applies to this division.

(1)

“Air conveying system” means an air moving device, such as a fan or blower, associated ductwork, and a cyclone or other collection device, the purpose of which is to move material from one point to another by entrainment in a moving airstream.

(2)

“Design criteria” means the numerical as well as verbal description of the basis of design, including but not necessarily limited to design flow rates, temperatures, humidities, contaminant descriptions in terms of types and chemical species, mass emission rates, concentrations, and specification of desired results in terms of final emission rates and concentrations, and scopes of vendor supplies and owner-supplied equipment and utilities, and a description of any operational controls.

(3)

“Domestic waste” means combustible household waste, other than wet garbage, such as paper, cardboard, leaves, yard clippings, wood, or similar materials generated in a dwelling housing four (4) families or less, or on the real property on which the dwelling is situated.

(4)

“Fireplace” is defined in OAR 340-262-0450 (Definitions).

(5)

“Grants Pass Urban Growth Area” and “Grants Pass Area” means the area within the Grants Pass Urban Growth Boundary as shown on the Plan and Zoning Maps for the City of Grants Pass as of 1 February 1988.

(6)

“Klamath Falls Nonattainment Area” means the area as defined in OAR 340-204-0010 (Definitions).

(7)

“La Grande Urban Growth Area” means the area within the La Grande Urban Growth Boundary as shown on the Plan and Zoning Maps for the City of La Grande as of 1 October 1991.

(8)

“Lakeview Urban Growth Area” means the area within the Lakeview Urban Growth Boundary as shown on the Plan and Zoning Maps for the Town of Lakeview as of 25 October 1993.

(9)

“Open burning” means burning conducted in such a manner that combustion air and combustion products may not be effectively controlled including, but not limited to, burning conducted in open outdoor fires, burn barrels, and backyard incinerators.

(10)

“Rebuilt boiler” means a physical change after April 29, 1988, to a wood-waste boiler or its air-contaminant emission control system which is not considered a modified source and for which the fixed, depreciable capital cost of added or replacement components equals or exceeds fifty percent of the fixed depreciable cost of a new component which has the same productive capacity.

(11)

“Refuse” means unwanted material.

(12)

“Refuse burning equipment” means a device designed to reduce the volume of solid, liquid, or gaseous refuse by combustion.

(13)

“Wigwam waste burner” means a burner which consists of a single combustion chamber, has the general features of a truncated cone, and is used for the incineration of wastes.

(14)

“Wood waste boiler” means equipment which uses indirect heat transfer from the products of combustion of wood waste to provide heat or power.
NOTE: This rule is included in the State of Oregon Clean Air Act Implementation Plan that EQC adopted under OAR 340-200-0040 (State of Oregon Clean Air Act Implementation Plan).
340‑240‑0010
Purpose
340‑240‑0020
Emission Limitations
340‑240‑0030
Definitions
340‑240‑0050
Compliance Testing Requirements
340‑240‑0100
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Applicability
340‑240‑0110
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wood Waste Boilers
340‑240‑0120
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Veneer Dryer Emission Limitations
340‑240‑0130
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Air Conveying Systems (Medford-Ashland AQMA Only)
340‑240‑0140
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wood Particle Dryers at Particleboard Plants
340‑240‑0150
Hardboard Manufacturing Plants
340‑240‑0160
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wigwam Waste Burners
340‑240‑0180
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Control of Fugitive Emissions (Medford-Ashland AQMA Only)
340‑240‑0190
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Requirement for Operation and Maintenance Plans (Medford-Ashland AQMA Only)
340‑240‑0210
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Continuous Monitoring
340‑240‑0220
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Source Testing
340‑240‑0250
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Open Burning
340‑240‑0300
La Grande Urban Growth Area: Applicability
340‑240‑0320
La Grande Urban Growth Area: Wood-Waste Boilers
340‑240‑0330
La Grande Urban Growth Area: Wood Particle Dryers at Particleboard Plants
340‑240‑0340
La Grande Urban Growth Area: Hardboard Manufacturing Plants
340‑240‑0350
La Grande Urban Growth Area: Air Conveying Systems
340‑240‑0360
La Grande Urban Growth Area: Fugitive Emissions
340‑240‑0400
Lakeview Urban Growth Area: Applicability
340‑240‑0410
Lakeview Urban Growth Area: Control of Fugitive Emissions
340‑240‑0420
Lakeview Urban Growth Area: Requirement for Operation and Maintenance Plans
340‑240‑0430
Lakeview Urban Growth Area: Source Testing
340‑240‑0440
Lakeview Urban Growth Area: Open Burning
340‑240‑0500
Klamath Falls Nonattainment Area: Applicability
340‑240‑0510
Klamath Falls Nonattainment Area: Opacity Standard
340‑240‑0520
Klamath Falls Nonattainment Area: Control of Fugitive Emissions
340‑240‑0530
Klamath Falls Nonattainment Area: Requirement for Operation and Maintenance Plans
340‑240‑0540
Klamath Falls Nonattainment Area: Compliance Schedule for Existing Industrial Sources
340‑240‑0550
Klamath Falls Nonattainment Area: Requirements for New Sources When Using Residential Wood Fuel-Fired Device Offsets
340‑240‑0560
Klamath Falls Nonattainment Area: Real and Permanent PM2.5 and PM10 Offsets
340‑240‑0570
Klamath Falls Nonattainment Area Contingency Measures: Applicability
340‑240‑0580
Klamath Falls Nonattainment Area Contingency Measures: Existing Industrial Sources Control Efficiency
340‑240‑0610
Klamath Falls Nonattainment Area Contingency Measures: Continuous Monitoring for Industrial Sources
340‑240‑0620
Klamath Falls Nonattainment Area Contingency Measures: Contingency Measures: New Industrial Sources
340‑240‑0630
Klamath Falls Nonattainment Area Contingency Measures: Contingency Enhanced Curtailment of Use of Solid Fuel Burning Devices and Fireplaces
Last Updated

Jun. 8, 2021

Rule 340-240-0030’s source at or​.us