OAR 340-240-0110
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wood Waste Boilers


(1)

No person may cause or permit the emission of particulate matter from any boiler with a heat input capacity greater than 35 million Btu/hour unless the boiler has been equipped with emission control devices which:

(a)

Limits emissions of particulate matter to LAER as defined by DEQ at the time DEQ approves the control device; and

(b)

Limits visible emissions such that opacity does not exceed 5% as a six minute average, unless the permittee demonstrates by source test that emissions can be limited to LAER at higher visible emissions, but in no case may emissions equal or exceed 10% opacity as a six minute average. Specific opacity limits will be included in the permit for each affected source.

(2)

For boilers existing in the baseline period with a heat input capacity greater than 35 million Btu/hour, boiler mass emission limits for the purpose of establishing the facility’s netting basis under OAR 340-222-0046 (Netting Basis) will be based on particulate matter emissions of 0.030 grains per dry standard cubic foot, corrected to 12% CO2.

(3)

Rebuilt Boilers are subject to OAR 340-240-0110 (Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wood Waste Boilers)(1). Boiler mass emissions for purposes of OAR 340-222-0041 (Source Specific Annual PSEL) will be based on LAER at the time DEQ approves the rebuilt boiler.
NOTE: This rule is included in the State of Oregon Clean Air Act Implementation Plan that EQC adopted under OAR 340-200-0040 (State of Oregon Clean Air Act Implementation Plan).

Source: Rule 340-240-0110 — Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wood Waste Boilers, https://secure.­sos.­state.­or.­us/oard/view.­action?ruleNumber=340-240-0110.

340‑240‑0010
Purpose
340‑240‑0020
Emission Limitations
340‑240‑0030
Definitions
340‑240‑0050
Compliance Testing Requirements
340‑240‑0100
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Applicability
340‑240‑0110
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wood Waste Boilers
340‑240‑0120
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Veneer Dryer Emission Limitations
340‑240‑0130
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Air Conveying Systems (Medford-Ashland AQMA Only)
340‑240‑0140
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wood Particle Dryers at Particleboard Plants
340‑240‑0150
Hardboard Manufacturing Plants
340‑240‑0160
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Wigwam Waste Burners
340‑240‑0180
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Control of Fugitive Emissions (Medford-Ashland AQMA Only)
340‑240‑0190
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Requirement for Operation and Maintenance Plans (Medford-Ashland AQMA Only)
340‑240‑0210
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Continuous Monitoring
340‑240‑0220
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Source Testing
340‑240‑0250
Medford-Ashland Air Quality Maintenance Area and Grants Pass Urban Growth Area: Open Burning
340‑240‑0300
La Grande Urban Growth Area: Applicability
340‑240‑0320
La Grande Urban Growth Area: Wood-Waste Boilers
340‑240‑0330
La Grande Urban Growth Area: Wood Particle Dryers at Particleboard Plants
340‑240‑0340
La Grande Urban Growth Area: Hardboard Manufacturing Plants
340‑240‑0350
La Grande Urban Growth Area: Air Conveying Systems
340‑240‑0360
La Grande Urban Growth Area: Fugitive Emissions
340‑240‑0400
Lakeview Urban Growth Area: Applicability
340‑240‑0410
Lakeview Urban Growth Area: Control of Fugitive Emissions
340‑240‑0420
Lakeview Urban Growth Area: Requirement for Operation and Maintenance Plans
340‑240‑0430
Lakeview Urban Growth Area: Source Testing
340‑240‑0440
Lakeview Urban Growth Area: Open Burning
340‑240‑0500
Klamath Falls Nonattainment Area: Applicability
340‑240‑0510
Klamath Falls Nonattainment Area: Opacity Standard
340‑240‑0520
Klamath Falls Nonattainment Area: Control of Fugitive Emissions
340‑240‑0530
Klamath Falls Nonattainment Area: Requirement for Operation and Maintenance Plans
340‑240‑0540
Klamath Falls Nonattainment Area: Compliance Schedule for Existing Industrial Sources
340‑240‑0550
Klamath Falls Nonattainment Area: Requirements for New Sources When Using Residential Wood Fuel-Fired Device Offsets
340‑240‑0560
Klamath Falls Nonattainment Area: Real and Permanent PM2.5 and PM10 Offsets
340‑240‑0570
Klamath Falls Nonattainment Area Contingency Measures: Applicability
340‑240‑0580
Klamath Falls Nonattainment Area Contingency Measures: Existing Industrial Sources Control Efficiency
340‑240‑0610
Klamath Falls Nonattainment Area Contingency Measures: Continuous Monitoring for Industrial Sources
340‑240‑0620
Klamath Falls Nonattainment Area Contingency Measures: Contingency Measures: New Industrial Sources
340‑240‑0630
Klamath Falls Nonattainment Area Contingency Measures: Contingency Enhanced Curtailment of Use of Solid Fuel Burning Devices and Fireplaces
Last Updated

Jun. 8, 2021

Rule 340-240-0110’s source at or​.us