ORS 479.255
Smoke alarm or smoke detector required in certain structures

  • alarms and devices for persons who are hard of hearing

(1)

Every dwelling unit regulated under ORS chapter 90, every lodging house and every hotel guest room shall contain an approved and properly functioning smoke alarm or smoke detector, installed in accordance with the state building code and rules of the State Fire Marshal.

(2)

A hotel shall provide no fewer than one smoke alarm for persons who are hard of hearing and one door knock device for each 75, or fraction thereof, rooms of the hotel that are regularly used for sleeping.

(3)

If a person renting a room in a hotel requests a room with a smoke detector or a smoke alarm for persons who are hard of hearing and a door knock device, the landlord shall:

(a)

Install a portable smoke alarm for persons who are hard of hearing and a door knock device; or

(b)

Provide the person with a room in which a smoke detector or smoke alarm for persons who are hard of hearing and a door knock device have been permanently installed.

(4)

The landlord may require a guest to pay a refundable deposit if the landlord provides the smoke alarm for persons who are hard of hearing under subsection (3)(a) of this section.

(5)

A hotel shall provide a printed notice of the requirements of subsection (3) of this section, posted conspicuously at the place of registration or in each guest room. [1979 c.642 §2; 1989 c.247 §2; 1999 c.307 §2; 2007 c.70 §273]

Source: Section 479.255 — Smoke alarm or smoke detector required in certain structures; alarms and devices for persons who are hard of hearing, https://www.­oregonlegislature.­gov/bills_laws/ors/ors479.­html.

479.015
Smoking in public elevator prohibited
479.155
Plan of proposed construction or alteration
479.165
Certification of fire officials
479.168
Definitions for ORS 479.168 to 479.190 and 479.990
479.170
Ordering repair of, or removal of material from, buildings
479.180
Appeal from order to comply with fire prevention statutes
479.190
Liability in damages for failure to comply with order under ORS 479.170
479.195
Assembly occupancy limits
479.200
Fire protection water supply for public buildings
479.210
“Institution” defined for ORS 479.215 to 479.220
479.215
Institution not to be licensed or certificated unless in compliance with fire safety requirements
479.217
Temporary permit in lieu of inspection approval under ORS 479.215
479.220
Institution inspection by State Fire Marshal
479.250
Definitions for ORS 479.250 to 479.305
479.255
Smoke alarm or smoke detector required in certain structures
479.257
Design features required for certain smoke alarms
479.258
Provision of notice of smoke alarm or smoke detector requirements for persons who are hard of hearing
479.260
Transfer of dwelling unit or lodging house without smoke alarm or smoke detector prohibited
479.265
Action for unlawful transfer of dwelling unit
479.270
Owner of rental dwelling unit to supply, install and maintain smoke alarm or smoke detector
479.275
Tenant of rental dwelling unit to test smoke alarm or smoke detector and replace dead batteries
479.280
Lack of properly operating smoke alarm or smoke detector
479.285
Owner to maintain and test certain smoke alarms and smoke detectors
479.290
Certain persons not liable for damages resulting from mechanical failure of smoke alarm or smoke detector
479.295
State Fire Marshal to adopt rules setting standards and providing for implementation of certain laws governing smoke alarms and smoke detectors
479.297
Ionization smoke alarms
479.300
Removing or tampering with smoke alarm or smoke detector prohibited
479.305
Smoking policy disclosure
479.510
Short title
479.520
Purpose
479.525
Application of Electrical Safety Law
479.530
Definitions for ORS 479.510 to 479.945 and 479.995
479.540
Exemptions
479.545
License required of state employee
479.550
No work on new electrical installation until permit issued
479.560
Issuance of permit
479.565
Master individual inspection permits
479.570
Energizing of electrical installations
479.610
Installation of uncertified electrical product prohibited
479.620
Certain electrical license required
479.630
Requirements for obtaining licenses
479.632
Applicant training or experience obtained in another state
479.670
Maintenance of action or suit by unlicensed person prohibited
479.680
Adoption of rules by Electrical and Elevator Board
479.710
Electrical installations must meet minimum safety standards
479.730
Adoption of rules by Director of Department of Consumer and Business Services
479.740
Factors to be considered in adopting rules
479.760
Certification of electrical products
479.770
Approved electric ignition pilot required on certain appliances
479.810
Administration and enforcement
479.815
Inspector conflicts of interest
479.820
Duties and powers in enforcing law
479.835
Recovery of purchase price of product not meeting applicable laws
479.840
Fees
479.845
Limitation on use of local government fees
479.850
Disposition of receipts
479.853
Appeal procedure
479.854
Authority of municipality to require license
479.855
City and county inspection and enforcement programs
479.860
Persons authorized to design, plan and lay out electrical installations
479.870
Electrical and Elevator Board to prescribe uniform fee calculation and permit format
479.905
Definitions for ORS 479.870 and 479.905 to 479.945
479.910
Limited energy technician license
479.915
Limited energy technician license requirements
479.940
Activities not subject to licensure under ORS 479.510 to 479.945
479.943
Activities not subject to licensure under ORS 479.905 to 479.945
479.945
Restricted energy contractor’s license
479.950
Minimum safety standards
479.990
Penalties
479.995
Civil penalty for violation of ORS 479.510 to 479.945